Select By Category / Brand
By Expert Care
Elderly Care
Critical Care
Accident Recovery
Post Operative Care
By Product
Diabeties
Corporate Gifts
Diagnostic Device
Hospital
Hospital Bed
Intensive Care Devices
Mobility Aids
Orthopaedic Aids
Patient Care
Rental
Respiratory
Wheelchair
Xpert care devises
Hospital Furniture
By Product Variant
Corporate Gifts
Gluco Meters
BP Monitor
Infrared Thermometer
Pulse Oximeter
Thermometer
Manual Bed
Automatic Bed
Accesories
Air purifier
Anesthesia Workstation
Baby Warmers
C ARM
Color Doppler
CPAP
Defibrillators
Disposables
ECG Machine
Foetal
Foetal Monitor
Holter
Home Care
Incubators
Infusion Pumps
Laryngoscope
Nebuliser
Nursing Station
OC
Patient Monitor
Penlon Vapuriser
Phototherapy
Surgical Diathermy
Ultrasound
Ventilators
X Ray Machine
Consulting & OPD Equipments
Gynaec
MultiPurpose Utility Product
Paediatric
Patient Trasfer Equipments
Wardcare Essentials
Mobility Aids
Patient lifters
Toilet and Bath safety
Walker and stick
Ankle Supports
Body Belts and Braces
Cervical Aids
Compression Garments
Finger Splints
Fracture Aids
Knee Supports
Orthopaedic Aids
Silicone & Foot Care
Traction Kits
Wrist & Fore Arm
Air Bed
Backrest
Bed & Accecories
Diapers
Patient Care
Weighing scale
Rental
Accesories
APAP
BIPAP
CPAP
Mask
Nebulizers
Oxygen Concentrator
Suction Machine
Manual
Xpert care devises
Face Shields
Goggles
PPE Kit
Motorised
Consulting & OPD Equipments
Gynaec
MultiPurpose Utility Product
Paediatric
Patient Trasfer Equipments
Wardcare Essentials
Hospital Bed
Hospital Furniture
By Brand
BPL
Diamond
Omron
Hicks
Phoenix
Vissco
Drive Devilbiss
Mobilita
Karma
Tynor
Peddar Jhonson
Seni
Market
Ryder
Microtone
Eagle
Resmed
Medtech
Philips
Yuwell
Arcatron
Freedom
Toggle navigation
Home
Medi Products
Medi Aid Hospital
Xpert Care Devices
Medi Rental
Corporate Gift
Mega Deals
Medi Consult
Contact Us
Enquire Now
Previous
Next
+91 9821587656
contact@mediaidxpert.com
×
Call Now
+91 9821587656
contact@mediaidxpert.com
Connect us on WhatsApp
Your Enquiry
*
Name
*
Mobile Number
*
Email
*
Pincode
Full Address
Send Now
CLOSE
FILTERS
By Product Category
Respiratory
By Product Sub-Category
Accesories
APAP
BIPAP
CPAP
Mask
Nebulizers
Oxygen Concentrator
Suction Machine
By Product Brand
Resmed
Medtech
Philips
Drive Devilbiss
BPL
Yuwell
Airfit N20 Cushion
Specifications
Height: 10 cm
Weight: 50 gm
Breadth: 10 cm
Length: 10 cm
Airfit N20 Cushion
Specifications
Height: 10 cm
Weight: 50 gm
Breadth: 10 cm
Length: 10 cm
Airfit F20 Cushion
Specifications
Height: 20 cm
Weight: 150 gm
Breadth: 20 cm
Length: 20 cm
Airfit F20 Cushion
Specifications
Height: 20 cm
Weight: 150 gm
Breadth: 20 cm
Length: 20 cm
Airfit N20 Frame SYS
Specifications
Height: 20 cm
Weight: 200 gm
Breadth: 20 cm
Length: 20 cm
Airfit N20 Frame SYS
Specifications
Height: 20 cm
Weight: 200 gm
Breadth: 20 cm
Length: 20 cm
Airfit F20 Frame SYS
Specifications
Height: 20 cm
Weight: 200 gm
Breadth: 20 cm
Length: 20 cm
Airfit F20 Frame SYS
Specifications
Height: 20 cm
Weight: 200 gm
Breadth: 20 cm
Length: 20 cm
Airfit F20 Headgear
Specifications
Height: 10 cm
Weight: 50 gm
Breadth: 10 cm
Length: 10 cm
Airfit F20 Headgear
Specifications
Height: 10 cm
Weight: 50 gm
Breadth: 10 cm
Length: 10 cm
Airfit N20 Headgear
Specifications
Height: 20 cm
Weight: 50 gm
Breadth: 20 cm
Length: 20 cm
Airfit N20 Headgear
Specifications
Height: 20 cm
Weight: 50 gm
Breadth: 20 cm
Length: 20 cm
Filter for S9 AirSense (pack of 3)
Specifications
Height: 2 cm
Weight: 5 gm
Breadth: 5 cm
Length: 10 cm
Filter for S9 AirSense (pack of 3)
Specifications
Height: 2 cm
Weight: 5 gm
Breadth: 5 cm
Length: 10 cm
AirMini Filter (Pack of 3)
Specifications
Height: 2 cm
Weight: 5 gm
Breadth: 2 cm
Length: 5 cm
AirMini Filter (Pack of 3)
Specifications
Height: 2 cm
Weight: 5 gm
Breadth: 2 cm
Length: 5 cm
SlimLine Tube
Specifications
Height: 150 mm
Weight: 100 gm
Breadth: 150 mm
Length: 200 mm
SlimLine Tube
Specifications
Height: 150 mm
Weight: 100 gm
Breadth: 150 mm
Length: 200 mm
ClimateLine Tube
Specifications
Height: 20 cm
Weight: 200 gm
Breadth: 20 cm
Length: 20 cm
Inner diameter: 0.6” (15 mm)
Length of Tube: 6’6” (2.0 m)
Material: Flexible plastic and electrical components.
ClimateLine Tube
Specifications
Height: 20 cm
Weight: 200 gm
Breadth: 20 cm
Length: 20 cm
Inner diameter: 0.6” (15 mm)
Length of Tube: 6’6” (2.0 m)
Material: Flexible plastic and electrical components.
Humid X Plus - Pack of 6
Specifications
Height: 5 cm
Weight: 50 gm
Breadth: 10 cm
Length: 10 cm
Humid X Plus - Pack of 6
Specifications
Height: 5 cm
Weight: 50 gm
Breadth: 10 cm
Length: 10 cm
HumidAir Standard Tub
Specifications
Height: 5 cm
Weight: 100 gm
Breadth: 10 cm
Length: 10 cm
HumidAir Standard Tub
Specifications
Height: 5 cm
Weight: 100 gm
Breadth: 10 cm
Length: 10 cm
Humid X Plus - Pack of 3
Specifications
Height: 5 cm
Weight: 100 gm
Breadth: 10 cm
Length: 10 cm
Humid X Plus - Pack of 3
Specifications
Height: 5 cm
Weight: 100 gm
Breadth: 10 cm
Length: 10 cm
Resmed Airstart 10 APAP
Specifications
Height: 116 mm
Weight: 1106 gm
Breadth: 205 mm
Length: 150 mm
Sound pressure level: 26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode)
Modes: CPAP, APAP, Ramp
Sound power level: 26.6 dBA with uncertainty of 2 dBA
Peak power consumption: 104W (108VA)
Operating pressure range: 4–20 cm H2O
Supplemental oxygen Maximum flow Recommended maximum flow: 4 L/min
Power supply unit: 90W power supply unit
Storage and transport humidity: 5 to 95% relative humidity, non-condensing
Storage and transport temperature: -20°C to +60°C
Operating humidity: 10 to 95% relative humidity, non-condensing
Housing construction: Flame retardant engineering thermoplastic
Air outlet: 22 mm air outlet complies with ISO 5356-1:2004
Typical power consumption: 53W (57VA)
Sensors
Pressure sensor: Internally located at device outlet, analogue gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitude Sea level to 2,591 m; air pressure range 1013 hPa to 738 hPa
Operating temperature +5°C to +35°C
Maximum single fault steady-state pressure
The Device will shut down in the presence of a single fault if the steady-state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec.
Resmed Airstart 10 APAP
Specifications
Height: 116 mm
Weight: 1106 gm
Breadth: 205 mm
Length: 150 mm
Sound pressure level: 26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode)
Modes: CPAP, APAP, Ramp
Sound power level: 26.6 dBA with uncertainty of 2 dBA
Peak power consumption: 104W (108VA)
Operating pressure range: 4–20 cm H2O
Supplemental oxygen Maximum flow Recommended maximum flow: 4 L/min
Power supply unit: 90W power supply unit
Storage and transport humidity: 5 to 95% relative humidity, non-condensing
Storage and transport temperature: -20°C to +60°C
Operating humidity: 10 to 95% relative humidity, non-condensing
Housing construction: Flame retardant engineering thermoplastic
Air outlet: 22 mm air outlet complies with ISO 5356-1:2004
Typical power consumption: 53W (57VA)
Sensors
Pressure sensor: Internally located at device outlet, analogue gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitude Sea level to 2,591 m; air pressure range 1013 hPa to 738 hPa
Operating temperature +5°C to +35°C
Maximum single fault steady-state pressure
The Device will shut down in the presence of a single fault if the steady-state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec.
Resmed AirCurve™ 10 V Auto
Specifications
Height 116 mm
Weight 1248 gm
Breadth 150 mm
Length 255 mm
Sound pressure level
Supplemental oxygen Maximum flow 15 L/min (CPAP, S); 4 L/min (VAuto)
Storage and transport humidity 5 to 95%relative humidity, non-condensing
Ramp Time You can set your Ramp Time to Off or between 5 to 45 minutes.
Water capacity: To maximum fill line 380 mL
Air outlet 22 mm
Typical power consumption 53W (57VA)
Sensors Pressure sensor: Internally located at device outlet, analoguegauge pressure type, -5 to +45cmH2O (-5 to +45 hPa); Flow sensor:Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitude Sea level to 2,591m; air pressure range 1013hPa to 738 hPa
Maximum single fault steady state pressure Device will shut down in the presence of a single fault if the steady state pressure exceeds:30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
Modes S, VAuto, CPAP
Sound power level Pressure level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:26.6 dBA with uncertainty of 2 dBAStandard:26.6 dBA with uncertainty of 2 dBAPower level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:34.6 dBA with uncertainty of 2 dBAStandard:34.6 dBA with uncertainty of 2 dBADeclared dual-number noise emission values in accordance with ISO4871:1996.
Peak power consumption 104W (108VA)
Operating pressure range S, VAuto: 2 to 25cm H2O (2 to 25 hPa); CPAP: 4 to 20cmH2O (4 to 20 hPa)
Power supply unit 90W power supply unit; AC input range:100–240V, 50–60Hz 1.0–1.5A, Class II115V, 400Hz 1.5A, Class II (nominal for aircraft use); DC output:24V 3.75A
Storage and transport temperature -20°C to +60°C
Operating humidity 10 to 95% relative humidity, non-condensin
Housing construction Flame retardant engineering thermoplastic
Operating temperature +5°C to +35°C Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room. Under extreme ambient temperature conditions (40°C) the device remains safe.
Wireless Module Technology used:4G, 2G. It is recommended that the device is a minimum distance of 2 cm from the body during operation. Not applicable to masks, tubes or accessories. Technology may not be available in all regions
Resmed AirCurve™ 10 V Auto
Specifications
Height 116 mm
Weight 1248 gm
Breadth 150 mm
Length 255 mm
Sound pressure level
Supplemental oxygen Maximum flow 15 L/min (CPAP, S); 4 L/min (VAuto)
Storage and transport humidity 5 to 95%relative humidity, non-condensing
Ramp Time You can set your Ramp Time to Off or between 5 to 45 minutes.
Water capacity: To maximum fill line 380 mL
Air outlet 22 mm
Typical power consumption 53W (57VA)
Sensors Pressure sensor: Internally located at device outlet, analoguegauge pressure type, -5 to +45cmH2O (-5 to +45 hPa); Flow sensor:Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitude Sea level to 2,591m; air pressure range 1013hPa to 738 hPa
Maximum single fault steady state pressure Device will shut down in the presence of a single fault if the steady state pressure exceeds:30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
Modes S, VAuto, CPAP
Sound power level Pressure level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:26.6 dBA with uncertainty of 2 dBAStandard:26.6 dBA with uncertainty of 2 dBAPower level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:34.6 dBA with uncertainty of 2 dBAStandard:34.6 dBA with uncertainty of 2 dBADeclared dual-number noise emission values in accordance with ISO4871:1996.
Peak power consumption 104W (108VA)
Operating pressure range S, VAuto: 2 to 25cm H2O (2 to 25 hPa); CPAP: 4 to 20cmH2O (4 to 20 hPa)
Power supply unit 90W power supply unit; AC input range:100–240V, 50–60Hz 1.0–1.5A, Class II115V, 400Hz 1.5A, Class II (nominal for aircraft use); DC output:24V 3.75A
Storage and transport temperature -20°C to +60°C
Operating humidity 10 to 95% relative humidity, non-condensin
Housing construction Flame retardant engineering thermoplastic
Operating temperature +5°C to +35°C Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room. Under extreme ambient temperature conditions (40°C) the device remains safe.
Wireless Module Technology used:4G, 2G. It is recommended that the device is a minimum distance of 2 cm from the body during operation. Not applicable to masks, tubes or accessories. Technology may not be available in all regions
Resmed AirSense 10 Autoset Tripack 3G CPAP Device
Specifications
Height 116 mm
Weight 1248 gm
Breadth 255 mm
Length 150 mm
Pressure measurement tolerance ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
Flow measurement tolerance ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
Peak power consumption 104W (108VA)
Operating pressure range 4 to 20 cm H2O
Supplemental oxygen Maximum flow 4 L/min
Power supply unit 90W power supply unit
Storage and transport humidity 5 to 95% relative humidity, non-condensing
Storage and transport temperature -4°F to +140°F (-20°C to +60°C)
Operating humidity 10 to 95% relative humidity, non-condensing
Housing construction Flame retardant engineering thermoplastic
Water capacity: To maximum fill line 380 mL
Air outlet 22 mm (complies with ISO 5356-1:2004)
Typical power consumption 53W (57VA)
Sensors Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitude Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
Operating temperature +41°F to +95°F (+5°C to +35°C)
Maximum single fault steady state pressure Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
Modes CPAP
Resmed AirSense 10 Autoset Tripack 3G CPAP Device
Specifications
Height 116 mm
Weight 1248 gm
Breadth 255 mm
Length 150 mm
Pressure measurement tolerance ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
Flow measurement tolerance ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
Peak power consumption 104W (108VA)
Operating pressure range 4 to 20 cm H2O
Supplemental oxygen Maximum flow 4 L/min
Power supply unit 90W power supply unit
Storage and transport humidity 5 to 95% relative humidity, non-condensing
Storage and transport temperature -4°F to +140°F (-20°C to +60°C)
Operating humidity 10 to 95% relative humidity, non-condensing
Housing construction Flame retardant engineering thermoplastic
Water capacity: To maximum fill line 380 mL
Air outlet 22 mm (complies with ISO 5356-1:2004)
Typical power consumption 53W (57VA)
Sensors Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitude Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
Operating temperature +41°F to +95°F (+5°C to +35°C)
Maximum single fault steady state pressure Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
Modes CPAP
Resmed AirMini portable CPAP Device
Specifications
Height 52 mm
Weight 300 gm
Breadth 84 mm
Length 136 mm
Housing construction Flame retardant engineering thermoplastic
Air outlet Proprietary connector, 16mm inner diameter. Not compatible with EN ISO 5356-1 connectors
Standby power consumption 1 W
Power supply unit AC input range: 100–240V, 50–60Hz, 0.5-0.3A 115V, 400Hz for aircraft use, 0.4A
Typical power consumption 6.3W
Peak power consumption 27W
Operating temperature +41°F to +95°F (+5°C to +35°C)
Operating humidity 10 to 95% relative humidity, noncondensing
Storage and transport temperature -13°F to +158°F (-25°C to +70°C)
Storage and transport humidity 5 to 95% relative humidity, noncondensing
Operating altitude Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
Modes CPAP, APAP, For Her
Resmed AirMini portable CPAP Device
Specifications
Height 52 mm
Weight 300 gm
Breadth 84 mm
Length 136 mm
Housing construction Flame retardant engineering thermoplastic
Air outlet Proprietary connector, 16mm inner diameter. Not compatible with EN ISO 5356-1 connectors
Standby power consumption 1 W
Power supply unit AC input range: 100–240V, 50–60Hz, 0.5-0.3A 115V, 400Hz for aircraft use, 0.4A
Typical power consumption 6.3W
Peak power consumption 27W
Operating temperature +41°F to +95°F (+5°C to +35°C)
Operating humidity 10 to 95% relative humidity, noncondensing
Storage and transport temperature -13°F to +158°F (-25°C to +70°C)
Storage and transport humidity 5 to 95% relative humidity, noncondensing
Operating altitude Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
Modes CPAP, APAP, For Her
Resmed Floton Auto CPAP
Specifications
Height 93 mm
Weight 1.2 kg
Breadth 117 mm
Length 170 mm
Sound power level <29 dB (A)
Operating pressure range 4–20 cm H2O
Power supply unit 100-240 VAC, 50-60 Hz, 24V, 2.5A Max
Operating humidity 10 to 93% relative humidity, non-condensing
Operating temperature +5°C to +35°C
Ramp Time 0-60 Min adjustable 1Min /Step
Resmed Floton Auto CPAP
Specifications
Height 93 mm
Weight 1.2 kg
Breadth 117 mm
Length 170 mm
Sound power level <29 dB (A)
Operating pressure range 4–20 cm H2O
Power supply unit 100-240 VAC, 50-60 Hz, 24V, 2.5A Max
Operating humidity 10 to 93% relative humidity, non-condensing
Operating temperature +5°C to +35°C
Ramp Time 0-60 Min adjustable 1Min /Step
Resmed AirFit F30 Full Face Mask
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed AirFit F30 Full Face Mask
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed Mirage Quattro Full Face Mask
Specifications
Height 186 mm
Weight 200 gm
Breadth 109 mm
Length 108 mm
Resmed Mirage Quattro Full Face Mask
Specifications
Height 186 mm
Weight 200 gm
Breadth 109 mm
Length 108 mm
Resmed Full face mask AirFit F20
Specifications
Height 154 mm
Weight 200 gm
Breadth 159 mm
Length 147 mm
Resmed Full face mask AirFit F20
Specifications
Height 154 mm
Weight 200 gm
Breadth 159 mm
Length 147 mm
Resmed Full Face mask AcuCare F1 - 4
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed Full Face mask AcuCare F1 - 4
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed Full Face mask AcuCare F1 - 0
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed Full Face mask AcuCare F1 - 0
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed Full Face mask AcuCare F1 - 1
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed Full Face mask AcuCare F1 - 1
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed AirFit P10 Nasal Pillow Mask
Specifications
Height 590 mm
Weight 200 gm
Breadth 149 mm
Length 30 mm
Resmed AirFit P10 Nasal Pillow Mask
Specifications
Height 590 mm
Weight 200 gm
Breadth 149 mm
Length 30 mm
Resmed P10 AirMini Mask Pack
Specifications
Height 37 mm
Weight 50 gm
Breadth 149 mm
Length 175 mm
Resmed P10 AirMini Mask Pack
Specifications
Height 37 mm
Weight 50 gm
Breadth 149 mm
Length 175 mm
Resmed AirFit P30i Nasal Pillow Mask (S)
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed AirFit P30i Nasal Pillow Mask (S)
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed Nasal mask AirFit N20
Specifications
Height 339 mm
Weight 200 gm
Breadth 291 mm
Length 162 mm
Resmed Nasal mask AirFit N20
Specifications
Height 339 mm
Weight 200 gm
Breadth 291 mm
Length 162 mm
Resmed AirFit N30i Nasal Cradle Mask (STD)
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
Resmed AirFit N30i Nasal Cradle Mask (STD)
Specifications
Height 20 cm
Weight 200 gm
Breadth 20 cm
Length 20 cm
ResMed Mirage Micro Nasal Mask (M)
Specifications
Height 155 mm
Weight 200 gm
Breadth 91 mm
Length 98 mm
ResMed Mirage Micro Nasal Mask (M)
Specifications
Height 155 mm
Weight 200 gm
Breadth 91 mm
Length 98 mm
Resmed Nasal mask AirFit N20 (L)
Specifications
Height 339 mm
Weight 200 gm
Breadth 291 mm
Length 162 mm
Resmed Nasal mask AirFit N20 (L)
Specifications
Height 339 mm
Weight 200 gm
Breadth 291 mm
Length 162 mm
N20 AirMini Set Up pack
Specifications
Height 6 cm
Weight 250 gm
Breadth 15 cm
Length 25 cm
N20 AirMini Set Up pack
Specifications
Height 6 cm
Weight 250 gm
Breadth 15 cm
Length 25 cm
Handyneb Nebuliser
Handyneb Nebuliser
Handyneb Vaporiser
Handyneb Vaporiser
Drive Portable OC iGO2
Drive Portable OC iGO2
Philips Simply Go Portable OC
Philips Simply Go Portable OC
SimplyGo Mini Portable OC
SimplyGo Mini Portable OC
Drive Devilbiss Oxygen Concentrator
Drive Devilbiss Oxygen Concentrator
Philips Ever Flo OC
Philips Ever Flo OC
BPL Oxy 5 Neo Dual
BPL Oxy 5 Neo Dual
BPL Oxy 5 Neo
BPL Oxy 5 Neo
Yuwell Double Bottle Suction Machine
Yuwell Double Bottle Suction Machine
Yuwell Suction Machine
Yuwell Suction Machine
Resmed AirSense 10 Elite Tripack - 3G
Specifications
Height 116 mm
Weight 1248 gm
Breadth 255 mm
Length 150 mm
Pressure measurement tolerance ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
Flow measurement tolerance ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
Peak power consumption 104W (108VA)
Operating pressure range 4 to 20 cm H2O
Supplemental oxygen Maximum flow 4 L/min
Power supply unit 90W power supply unit
Storage and transport humidity 5 to 95% relative humidity, non-condensing
Storage and transport temperature -4°F to +140°F (-20°C to +60°C)
Operating humidity 10 to 95% relative humidity, non-condensing
Housing construction Flame retardant engineering thermoplastic
Water capacity: To maximum fill line 380 mL
Air outlet 22 mm (complies with ISO 5356-1:2004)
Typical power consumption 53W (57VA)
Sensors Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitude Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
Operating temperature +41°F to +95°F (+5°C to +35°C)
Maximum single fault steady state pressure Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
Modes CPAP
Resmed AirSense 10 Elite Tripack - 3G
Specifications
Height 116 mm
Weight 1248 gm
Breadth 255 mm
Length 150 mm
Pressure measurement tolerance ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
Flow measurement tolerance ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
Peak power consumption 104W (108VA)
Operating pressure range 4 to 20 cm H2O
Supplemental oxygen Maximum flow 4 L/min
Power supply unit 90W power supply unit
Storage and transport humidity 5 to 95% relative humidity, non-condensing
Storage and transport temperature -4°F to +140°F (-20°C to +60°C)
Operating humidity 10 to 95% relative humidity, non-condensing
Housing construction Flame retardant engineering thermoplastic
Water capacity: To maximum fill line 380 mL
Air outlet 22 mm (complies with ISO 5356-1:2004)
Typical power consumption 53W (57VA)
Sensors Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitude Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
Operating temperature +41°F to +95°F (+5°C to +35°C)
Maximum single fault steady state pressure Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
Modes CPAP
Enquiry Now
Call Now
+91 9821587656
contact@mediexpert.com
Your Enquiry
Name
Mobile Number
*
Email
Pincode
Full Address
Save
CLOSE
aaa