Airfit N20 Cushion

Specifications

  • Height:   10 cm
  • Weight:    50 gm
  • Breadth:    10 cm
  • Length:    10 cm

Airfit N20 Cushion

Specifications

  • Height:   10 cm
  • Weight:    50 gm
  • Breadth:    10 cm
  • Length:    10 cm




Airfit F20 Cushion

Specifications

  • Height:    20 cm
  • Weight:   150 gm
  • Breadth:    20 cm
  • Length:    20 cm

Airfit F20 Cushion

Specifications

  • Height:    20 cm
  • Weight:   150 gm
  • Breadth:    20 cm
  • Length:    20 cm




Airfit N20 Frame SYS

Specifications

  • Height:   20 cm
  • Weight:    200 gm
  • Breadth:    20 cm
  • Length:    20 cm

Airfit N20 Frame SYS

Specifications

  • Height:   20 cm
  • Weight:    200 gm
  • Breadth:    20 cm
  • Length:    20 cm




Airfit F20 Frame SYS

Specifications

  • Height:    20 cm
  • Weight:    200 gm
  • Breadth:    20 cm
  • Length:    20 cm

Airfit F20 Frame SYS

Specifications

  • Height:    20 cm
  • Weight:    200 gm
  • Breadth:    20 cm
  • Length:    20 cm




Airfit F20 Headgear

Specifications

  • Height:    10 cm
  • Weight:    50 gm
  • Breadth:    10 cm
  • Length:    10 cm

Airfit F20 Headgear

Specifications

  • Height:    10 cm
  • Weight:    50 gm
  • Breadth:    10 cm
  • Length:    10 cm




Airfit N20 Headgear

Specifications

  • Height:    20 cm
  • Weight:    50 gm
  • Breadth:    20 cm
  • Length:    20 cm

Airfit N20 Headgear

Specifications

  • Height:    20 cm
  • Weight:    50 gm
  • Breadth:    20 cm
  • Length:    20 cm




Filter for S9 AirSense (pack of 3)

Specifications

  • Height:    2 cm
  • Weight:    5 gm
  • Breadth:    5 cm
  • Length:    10 cm

Filter for S9 AirSense (pack of 3)

Specifications

  • Height:    2 cm
  • Weight:    5 gm
  • Breadth:    5 cm
  • Length:    10 cm




AirMini Filter (Pack of 3)

Specifications

  • Height:    2 cm
  • Weight:    5 gm
  • Breadth:    2 cm
  • Length:    5 cm

AirMini Filter (Pack of 3)

Specifications

  • Height:    2 cm
  • Weight:    5 gm
  • Breadth:    2 cm
  • Length:    5 cm




SlimLine Tube

Specifications

  • Height:    150 mm
  • Weight:    100 gm
  • Breadth:    150 mm
  • Length:    200 mm

SlimLine Tube

Specifications

  • Height:    150 mm
  • Weight:    100 gm
  • Breadth:    150 mm
  • Length:    200 mm




ClimateLine Tube

Specifications

  • Height:   20 cm
  • Weight:    200 gm
  • Breadth:    20 cm
  • Length:    20 cm
  • Inner diameter:    0.6” (15 mm)
  • Length of Tube:    6’6” (2.0 m)
  • Material:    Flexible plastic and electrical components.

ClimateLine Tube

Specifications

  • Height:   20 cm
  • Weight:    200 gm
  • Breadth:    20 cm
  • Length:    20 cm
  • Inner diameter:    0.6” (15 mm)
  • Length of Tube:    6’6” (2.0 m)
  • Material:    Flexible plastic and electrical components.




Humid X Plus - Pack of 6

Specifications

  • Height:   5 cm
  • Weight:    50 gm
  • Breadth:    10 cm
  • Length:    10 cm

Humid X Plus - Pack of 6

Specifications

  • Height:   5 cm
  • Weight:    50 gm
  • Breadth:    10 cm
  • Length:    10 cm




HumidAir Standard Tub

Specifications

  • Height:    5 cm
  • Weight:    100 gm
  • Breadth:    10 cm
  • Length:    10 cm

HumidAir Standard Tub

Specifications

  • Height:    5 cm
  • Weight:    100 gm
  • Breadth:    10 cm
  • Length:    10 cm




Humid X Plus - Pack of 3

Specifications

  • Height:   5 cm
  • Weight:    100 gm
  • Breadth:    10 cm
  • Length: 10 cm

Humid X Plus - Pack of 3

Specifications

  • Height:   5 cm
  • Weight:    100 gm
  • Breadth:    10 cm
  • Length: 10 cm




Resmed Airstart 10 APAP

Specifications

  • Height:    116 mm
  • Weight:     1106 gm
  • Breadth:     205 mm
  • Length:     150 mm
  • Sound pressure level:     26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode)
  • Modes:     CPAP, APAP, Ramp
  • Sound power level:     26.6 dBA with uncertainty of 2 dBA
  • Peak power consumption:     104W (108VA)
  • Operating pressure range:     4–20 cm H2O
  • Supplemental oxygen Maximum flow    Recommended maximum flow: 4 L/min
  • Power supply unit:     90W power supply unit
  • Storage and transport humidity:     5 to 95% relative humidity, non-condensing
  • Storage and transport temperature:     -20°C to +60°C
  • Operating humidity:     10 to 95% relative humidity, non-condensing
  • Housing construction:     Flame retardant engineering thermoplastic
  • Air outlet:     22 mm air outlet complies with ISO 5356-1:2004
  • Typical power consumption:     53W (57VA)

 

Sensors    

  • Pressure sensor: Internally located at device outlet, analogue gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 2,591 m; air pressure range 1013 hPa to 738 hPa
  • Operating temperature    +5°C to +35°C
  • Maximum single fault steady-state pressure  
  • The Device will shut down in the presence of a single fault if the steady-state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec.

Resmed Airstart 10 APAP

Specifications

  • Height:    116 mm
  • Weight:     1106 gm
  • Breadth:     205 mm
  • Length:     150 mm
  • Sound pressure level:     26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode)
  • Modes:     CPAP, APAP, Ramp
  • Sound power level:     26.6 dBA with uncertainty of 2 dBA
  • Peak power consumption:     104W (108VA)
  • Operating pressure range:     4–20 cm H2O
  • Supplemental oxygen Maximum flow    Recommended maximum flow: 4 L/min
  • Power supply unit:     90W power supply unit
  • Storage and transport humidity:     5 to 95% relative humidity, non-condensing
  • Storage and transport temperature:     -20°C to +60°C
  • Operating humidity:     10 to 95% relative humidity, non-condensing
  • Housing construction:     Flame retardant engineering thermoplastic
  • Air outlet:     22 mm air outlet complies with ISO 5356-1:2004
  • Typical power consumption:     53W (57VA)

 

Sensors    

  • Pressure sensor: Internally located at device outlet, analogue gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 2,591 m; air pressure range 1013 hPa to 738 hPa
  • Operating temperature    +5°C to +35°C
  • Maximum single fault steady-state pressure  
  • The Device will shut down in the presence of a single fault if the steady-state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec.




Resmed AirCurve™ 10 V Auto

Specifications

  • Height    116 mm
  • Weight    1248 gm
  • Breadth    150 mm
  • Length    255 mm
  • Sound pressure level    
  • Supplemental oxygen Maximum flow    15 L/min (CPAP, S); 4 L/min (VAuto)
  • Storage and transport humidity    5 to 95%relative humidity, non-condensing
  • Ramp Time    You can set your Ramp Time to Off or between 5 to 45 minutes.
  • Water capacity:    To maximum fill line 380 mL
  • Air outlet    22 mm
  • Typical power consumption    53W (57VA)
  • Sensors    Pressure sensor: Internally located at device outlet, analoguegauge pressure type, -5 to +45cmH2O (-5 to +45 hPa); Flow sensor:Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 2,591m; air pressure range 1013hPa to 738 hPa
  • Maximum single fault steady state pressure    Device will shut down in the presence of a single fault if the steady state pressure exceeds:30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes    S, VAuto, CPAP
  • Sound power level    Pressure level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:26.6 dBA with uncertainty of 2 dBAStandard:26.6 dBA with uncertainty of 2 dBAPower level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:34.6 dBA with uncertainty of 2 dBAStandard:34.6 dBA with uncertainty of 2 dBADeclared dual-number noise emission values in accordance with ISO4871:1996.
  • Peak power consumption    104W (108VA)
  • Operating pressure range    S, VAuto: 2 to 25cm H2O (2 to 25 hPa); CPAP: 4 to 20cmH2O (4 to 20 hPa)
  • Power supply unit    90W power supply unit; AC input range:100–240V, 50–60Hz 1.0–1.5A, Class II115V, 400Hz 1.5A, Class II (nominal for aircraft use); DC output:24V 3.75A
  • Storage and transport temperature    -20°C to +60°C
  • Operating humidity    10 to 95% relative humidity, non-condensin
  • Housing construction    Flame retardant engineering thermoplastic
  • Operating temperature    +5°C to +35°C Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room. Under extreme ambient temperature conditions (40°C) the device remains safe.
  • Wireless Module    Technology used:4G, 2G. It is recommended that the device is a minimum distance of 2 cm from the body during operation. Not applicable to masks, tubes or accessories. Technology may not be available in all regions
  •  

Resmed AirCurve™ 10 V Auto

Specifications

  • Height    116 mm
  • Weight    1248 gm
  • Breadth    150 mm
  • Length    255 mm
  • Sound pressure level    
  • Supplemental oxygen Maximum flow    15 L/min (CPAP, S); 4 L/min (VAuto)
  • Storage and transport humidity    5 to 95%relative humidity, non-condensing
  • Ramp Time    You can set your Ramp Time to Off or between 5 to 45 minutes.
  • Water capacity:    To maximum fill line 380 mL
  • Air outlet    22 mm
  • Typical power consumption    53W (57VA)
  • Sensors    Pressure sensor: Internally located at device outlet, analoguegauge pressure type, -5 to +45cmH2O (-5 to +45 hPa); Flow sensor:Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 2,591m; air pressure range 1013hPa to 738 hPa
  • Maximum single fault steady state pressure    Device will shut down in the presence of a single fault if the steady state pressure exceeds:30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes    S, VAuto, CPAP
  • Sound power level    Pressure level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:26.6 dBA with uncertainty of 2 dBAStandard:26.6 dBA with uncertainty of 2 dBAPower level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:34.6 dBA with uncertainty of 2 dBAStandard:34.6 dBA with uncertainty of 2 dBADeclared dual-number noise emission values in accordance with ISO4871:1996.
  • Peak power consumption    104W (108VA)
  • Operating pressure range    S, VAuto: 2 to 25cm H2O (2 to 25 hPa); CPAP: 4 to 20cmH2O (4 to 20 hPa)
  • Power supply unit    90W power supply unit; AC input range:100–240V, 50–60Hz 1.0–1.5A, Class II115V, 400Hz 1.5A, Class II (nominal for aircraft use); DC output:24V 3.75A
  • Storage and transport temperature    -20°C to +60°C
  • Operating humidity    10 to 95% relative humidity, non-condensin
  • Housing construction    Flame retardant engineering thermoplastic
  • Operating temperature    +5°C to +35°C Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room. Under extreme ambient temperature conditions (40°C) the device remains safe.
  • Wireless Module    Technology used:4G, 2G. It is recommended that the device is a minimum distance of 2 cm from the body during operation. Not applicable to masks, tubes or accessories. Technology may not be available in all regions
  •  




Resmed AirSense 10 Autoset Tripack 3G CPAP Device

Specifications

  • Height    116 mm
  • Weight    1248 gm
  • Breadth    255 mm
  • Length    150 mm
  • Pressure measurement tolerance    ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
  • Flow measurement tolerance    ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
  • Peak power consumption    104W (108VA)
  • Operating pressure range    4 to 20 cm H2O
  • Supplemental oxygen Maximum flow    4 L/min
  • Power supply unit    90W power supply unit
  • Storage and transport humidity    5 to 95% relative humidity, non-condensing
  • Storage and transport temperature    -4°F to +140°F (-20°C to +60°C)
  • Operating humidity    10 to 95% relative humidity, non-condensing
  • Housing construction    Flame retardant engineering thermoplastic
  • Water capacity:    To maximum fill line 380 mL
  • Air outlet    22 mm (complies with ISO 5356-1:2004)
  • Typical power consumption    53W (57VA)
  • Sensors    Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Maximum single fault steady state pressure    Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes    CPAP

Resmed AirSense 10 Autoset Tripack 3G CPAP Device

Specifications

  • Height    116 mm
  • Weight    1248 gm
  • Breadth    255 mm
  • Length    150 mm
  • Pressure measurement tolerance    ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
  • Flow measurement tolerance    ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
  • Peak power consumption    104W (108VA)
  • Operating pressure range    4 to 20 cm H2O
  • Supplemental oxygen Maximum flow    4 L/min
  • Power supply unit    90W power supply unit
  • Storage and transport humidity    5 to 95% relative humidity, non-condensing
  • Storage and transport temperature    -4°F to +140°F (-20°C to +60°C)
  • Operating humidity    10 to 95% relative humidity, non-condensing
  • Housing construction    Flame retardant engineering thermoplastic
  • Water capacity:    To maximum fill line 380 mL
  • Air outlet    22 mm (complies with ISO 5356-1:2004)
  • Typical power consumption    53W (57VA)
  • Sensors    Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Maximum single fault steady state pressure    Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes    CPAP




Resmed AirMini portable CPAP Device

Specifications

  • Height    52 mm
  • Weight    300 gm
  • Breadth    84 mm
  • Length    136 mm
  • Housing construction    Flame retardant engineering thermoplastic
  • Air outlet    Proprietary connector, 16mm inner diameter. Not compatible with EN ISO 5356-1 connectors
  • Standby power consumption    1 W
  • Power supply unit    AC input range: 100–240V, 50–60Hz, 0.5-0.3A 115V, 400Hz for aircraft use, 0.4A
  • Typical power consumption    6.3W
  • Peak power consumption    27W
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Operating humidity    10 to 95% relative humidity, noncondensing
  • Storage and transport temperature    -13°F to +158°F (-25°C to +70°C)
  • Storage and transport humidity    5 to 95% relative humidity, noncondensing
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Modes    CPAP, APAP, For Her

Resmed AirMini portable CPAP Device

Specifications

  • Height    52 mm
  • Weight    300 gm
  • Breadth    84 mm
  • Length    136 mm
  • Housing construction    Flame retardant engineering thermoplastic
  • Air outlet    Proprietary connector, 16mm inner diameter. Not compatible with EN ISO 5356-1 connectors
  • Standby power consumption    1 W
  • Power supply unit    AC input range: 100–240V, 50–60Hz, 0.5-0.3A 115V, 400Hz for aircraft use, 0.4A
  • Typical power consumption    6.3W
  • Peak power consumption    27W
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Operating humidity    10 to 95% relative humidity, noncondensing
  • Storage and transport temperature    -13°F to +158°F (-25°C to +70°C)
  • Storage and transport humidity    5 to 95% relative humidity, noncondensing
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Modes    CPAP, APAP, For Her




Resmed Floton Auto CPAP

Specifications

  • Height    93 mm
  • Weight    1.2 kg
  • Breadth    117 mm
  • Length    170 mm
  • Sound power level    <29 dB (A)
  • Operating pressure range    4–20 cm H2O
  • Power supply unit    100-240 VAC, 50-60 Hz, 24V, 2.5A Max
  • Operating humidity    10 to 93% relative humidity, non-condensing
  • Operating temperature    +5°C to +35°C
  • Ramp Time    0-60 Min adjustable 1Min /Step
     

Resmed Floton Auto CPAP

Specifications

  • Height    93 mm
  • Weight    1.2 kg
  • Breadth    117 mm
  • Length    170 mm
  • Sound power level    <29 dB (A)
  • Operating pressure range    4–20 cm H2O
  • Power supply unit    100-240 VAC, 50-60 Hz, 24V, 2.5A Max
  • Operating humidity    10 to 93% relative humidity, non-condensing
  • Operating temperature    +5°C to +35°C
  • Ramp Time    0-60 Min adjustable 1Min /Step
     




Resmed AirFit F30 Full Face Mask

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm

Resmed AirFit F30 Full Face Mask

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm




Resmed Mirage Quattro Full Face Mask

Specifications

  • Height    186 mm
  • Weight    200 gm
  • Breadth    109 mm
  • Length    108 mm

Resmed Mirage Quattro Full Face Mask

Specifications

  • Height    186 mm
  • Weight    200 gm
  • Breadth    109 mm
  • Length    108 mm




Resmed Full face mask AirFit F20

Specifications

  • Height    154 mm
  • Weight    200 gm
  • Breadth    159 mm
  • Length    147 mm

Resmed Full face mask AirFit F20

Specifications

  • Height    154 mm
  • Weight    200 gm
  • Breadth    159 mm
  • Length    147 mm




Resmed Full Face mask AcuCare F1 - 4

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm

Resmed Full Face mask AcuCare F1 - 4

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm




Resmed Full Face mask AcuCare F1 - 0

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm

Resmed Full Face mask AcuCare F1 - 0

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm




Resmed Full Face mask AcuCare F1 - 1

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm

Resmed Full Face mask AcuCare F1 - 1

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm




Resmed AirFit P10 Nasal Pillow Mask

Specifications

  • Height    590 mm
  • Weight    200 gm
  • Breadth    149 mm
  • Length    30 mm

Resmed AirFit P10 Nasal Pillow Mask

Specifications

  • Height    590 mm
  • Weight    200 gm
  • Breadth    149 mm
  • Length    30 mm




Resmed P10 AirMini Mask Pack

Specifications

  • Height    37 mm
  • Weight    50 gm
  • Breadth    149 mm
  • Length    175 mm
     

Resmed P10 AirMini Mask Pack

Specifications

  • Height    37 mm
  • Weight    50 gm
  • Breadth    149 mm
  • Length    175 mm
     




Resmed AirFit P30i Nasal Pillow Mask (S)

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm

Resmed AirFit P30i Nasal Pillow Mask (S)

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm




Resmed Nasal mask AirFit N20

Specifications

  • Height    339 mm
  • Weight    200 gm
  • Breadth    291 mm
  • Length    162 mm

Resmed Nasal mask AirFit N20

Specifications

  • Height    339 mm
  • Weight    200 gm
  • Breadth    291 mm
  • Length    162 mm




Resmed AirFit N30i Nasal Cradle Mask (STD)

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm

Resmed AirFit N30i Nasal Cradle Mask (STD)

Specifications

  • Height    20 cm
  • Weight    200 gm
  • Breadth    20 cm
  • Length    20 cm




ResMed Mirage Micro Nasal Mask (M)

Specifications

  • Height    155 mm
  • Weight    200 gm
  • Breadth    91 mm
  • Length    98 mm

ResMed Mirage Micro Nasal Mask (M)

Specifications

  • Height    155 mm
  • Weight    200 gm
  • Breadth    91 mm
  • Length    98 mm




Resmed Nasal mask AirFit N20 (L)

Specifications

  • Height    339 mm
  • Weight    200 gm
  • Breadth    291 mm
  • Length    162 mm

Resmed Nasal mask AirFit N20 (L)

Specifications

  • Height    339 mm
  • Weight    200 gm
  • Breadth    291 mm
  • Length    162 mm




N20 AirMini Set Up pack

Specifications

  • Height    6 cm
  • Weight    250 gm
  • Breadth    15 cm
  • Length    25 cm

N20 AirMini Set Up pack

Specifications

  • Height    6 cm
  • Weight    250 gm
  • Breadth    15 cm
  • Length    25 cm




Handyneb Nebuliser

Handyneb Nebuliser




Handyneb Vaporiser

Handyneb Vaporiser




Drive Portable OC iGO2

Drive Portable OC iGO2




Philips Simply Go Portable OC

Philips Simply Go Portable OC




SimplyGo Mini Portable OC

SimplyGo Mini Portable OC




Drive Devilbiss Oxygen Concentrator

Drive Devilbiss Oxygen Concentrator




Philips Ever Flo OC

Philips Ever Flo OC




BPL Oxy 5 Neo Dual

BPL Oxy 5 Neo Dual




BPL Oxy 5 Neo

BPL Oxy 5 Neo




Yuwell Double Bottle Suction Machine

Yuwell Double Bottle Suction Machine




Yuwell Suction Machine

Yuwell Suction Machine




Resmed AirSense 10 Elite Tripack - 3G

 

Specifications

  • Height    116 mm
  • Weight    1248 gm
  • Breadth    255 mm
  • Length    150 mm
  • Pressure measurement tolerance    ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
  • Flow measurement tolerance    ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
  • Peak power consumption    104W (108VA)
  • Operating pressure range    4 to 20 cm H2O
  • Supplemental oxygen Maximum flow    4 L/min
  • Power supply unit    90W power supply unit
  • Storage and transport humidity    5 to 95% relative humidity, non-condensing
  • Storage and transport temperature    -4°F to +140°F (-20°C to +60°C)
  • Operating humidity    10 to 95% relative humidity, non-condensing
  • Housing construction    Flame retardant engineering thermoplastic
  • Water capacity:    To maximum fill line 380 mL
  • Air outlet    22 mm (complies with ISO 5356-1:2004)
  • Typical power consumption    53W (57VA)
  • Sensors    Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Maximum single fault steady state pressure    Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes    CPAP

Resmed AirSense 10 Elite Tripack - 3G

 

Specifications

  • Height    116 mm
  • Weight    1248 gm
  • Breadth    255 mm
  • Length    150 mm
  • Pressure measurement tolerance    ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
  • Flow measurement tolerance    ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
  • Peak power consumption    104W (108VA)
  • Operating pressure range    4 to 20 cm H2O
  • Supplemental oxygen Maximum flow    4 L/min
  • Power supply unit    90W power supply unit
  • Storage and transport humidity    5 to 95% relative humidity, non-condensing
  • Storage and transport temperature    -4°F to +140°F (-20°C to +60°C)
  • Operating humidity    10 to 95% relative humidity, non-condensing
  • Housing construction    Flame retardant engineering thermoplastic
  • Water capacity:    To maximum fill line 380 mL
  • Air outlet    22 mm (complies with ISO 5356-1:2004)
  • Typical power consumption    53W (57VA)
  • Sensors    Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Maximum single fault steady state pressure    Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes    CPAP





aaa