Resmed AirMini portable CPAP Device

Specifications

  • Height    52 mm
  • Weight    300 gm
  • Breadth    84 mm
  • Length    136 mm
  • Housing construction    Flame retardant engineering thermoplastic
  • Air outlet    Proprietary connector, 16mm inner diameter. Not compatible with EN ISO 5356-1 connectors
  • Standby power consumption    1 W
  • Power supply unit    AC input range: 100–240V, 50–60Hz, 0.5-0.3A 115V, 400Hz for aircraft use, 0.4A
  • Typical power consumption    6.3W
  • Peak power consumption    27W
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Operating humidity    10 to 95% relative humidity, noncondensing
  • Storage and transport temperature    -13°F to +158°F (-25°C to +70°C)
  • Storage and transport humidity    5 to 95% relative humidity, noncondensing
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Modes    CPAP, APAP, For Her

Resmed AirMini portable CPAP Device

Specifications

  • Height    52 mm
  • Weight    300 gm
  • Breadth    84 mm
  • Length    136 mm
  • Housing construction    Flame retardant engineering thermoplastic
  • Air outlet    Proprietary connector, 16mm inner diameter. Not compatible with EN ISO 5356-1 connectors
  • Standby power consumption    1 W
  • Power supply unit    AC input range: 100–240V, 50–60Hz, 0.5-0.3A 115V, 400Hz for aircraft use, 0.4A
  • Typical power consumption    6.3W
  • Peak power consumption    27W
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Operating humidity    10 to 95% relative humidity, noncondensing
  • Storage and transport temperature    -13°F to +158°F (-25°C to +70°C)
  • Storage and transport humidity    5 to 95% relative humidity, noncondensing
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Modes    CPAP, APAP, For Her




Resmed Floton Auto CPAP

Specifications

  • Height    93 mm
  • Weight    1.2 kg
  • Breadth    117 mm
  • Length    170 mm
  • Sound power level    <29 dB (A)
  • Operating pressure range    4–20 cm H2O
  • Power supply unit    100-240 VAC, 50-60 Hz, 24V, 2.5A Max
  • Operating humidity    10 to 93% relative humidity, non-condensing
  • Operating temperature    +5°C to +35°C
  • Ramp Time    0-60 Min adjustable 1Min /Step
     

Resmed Floton Auto CPAP

Specifications

  • Height    93 mm
  • Weight    1.2 kg
  • Breadth    117 mm
  • Length    170 mm
  • Sound power level    <29 dB (A)
  • Operating pressure range    4–20 cm H2O
  • Power supply unit    100-240 VAC, 50-60 Hz, 24V, 2.5A Max
  • Operating humidity    10 to 93% relative humidity, non-condensing
  • Operating temperature    +5°C to +35°C
  • Ramp Time    0-60 Min adjustable 1Min /Step
     




Resmed AirSense 10 Elite Tripack - 3G

 

Specifications

  • Height    116 mm
  • Weight    1248 gm
  • Breadth    255 mm
  • Length    150 mm
  • Pressure measurement tolerance    ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
  • Flow measurement tolerance    ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
  • Peak power consumption    104W (108VA)
  • Operating pressure range    4 to 20 cm H2O
  • Supplemental oxygen Maximum flow    4 L/min
  • Power supply unit    90W power supply unit
  • Storage and transport humidity    5 to 95% relative humidity, non-condensing
  • Storage and transport temperature    -4°F to +140°F (-20°C to +60°C)
  • Operating humidity    10 to 95% relative humidity, non-condensing
  • Housing construction    Flame retardant engineering thermoplastic
  • Water capacity:    To maximum fill line 380 mL
  • Air outlet    22 mm (complies with ISO 5356-1:2004)
  • Typical power consumption    53W (57VA)
  • Sensors    Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Maximum single fault steady state pressure    Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes    CPAP

Resmed AirSense 10 Elite Tripack - 3G

 

Specifications

  • Height    116 mm
  • Weight    1248 gm
  • Breadth    255 mm
  • Length    150 mm
  • Pressure measurement tolerance    ±[0.5 cm H20 (0.5 hPa) + 4% of measured value]
  • Flow measurement tolerance    ±6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
  • Peak power consumption    104W (108VA)
  • Operating pressure range    4 to 20 cm H2O
  • Supplemental oxygen Maximum flow    4 L/min
  • Power supply unit    90W power supply unit
  • Storage and transport humidity    5 to 95% relative humidity, non-condensing
  • Storage and transport temperature    -4°F to +140°F (-20°C to +60°C)
  • Operating humidity    10 to 95% relative humidity, non-condensing
  • Housing construction    Flame retardant engineering thermoplastic
  • Water capacity:    To maximum fill line 380 mL
  • Air outlet    22 mm (complies with ISO 5356-1:2004)
  • Typical power consumption    53W (57VA)
  • Sensors    Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude    Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
  • Operating temperature    +41°F to +95°F (+5°C to +35°C)
  • Maximum single fault steady state pressure    Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes    CPAP